Strany 1 - MD2 Series Barcode Scanner

MD2 Series Barcode Scanner User Manual Version: MD2_UM_EN_V3.1.6C

Strany 2

6 Introduction to installation Note: If any of the below operation is incorrect, turn off the power immediately and check the scanner for any improper

Strany 3 - Contents

7 Scanning modes The scanner has two scanning modes: hand-held and auto-detection. When the scanner is scanning, ensure the scan line crosses every

Strany 4

8 Programming instruction Refer to the next page, the steps of programming are: 1. Scan the SETUP bar code on the parameter setting part. 2. Enter t

Strany 5 - Technical specifications

9 Interface selection This scanner supports interfaces such as keyboard wedge, RS-232 serial wedge, and USB interface. In most of the cases, simp

Strany 6

10 Keyboard wedge Keyboard type: As a keyboard interface, the scanner supports most of the popular PCs and IBM terminals. Keyboard layo

Strany 7 - Decode zone

11 SETUP Option bar code Option Alpha. entry 70us 80us 90us 100us 200us 01 02* 03 04 05 Delay-after-compound-key 0ms 10ms 20ms 40ms 80ms 00* 0

Strany 8 - Dimensions

12 RS-232 interface Flow control: None-The communication only uses TxD and RxD signals without any hardware or software handshaking protoc

Strany 9 - Parts of the scanner

13 SETUP Option bar code Option Alpha. entry Flow control None RTS/CTS (Host idle: Low RTS) RTS/CTS (Host idle: High RTS) XON/XOFF ACK/NAK 00

Strany 10 - Introduction to installation

14 Hand-held scan & some global settings Scanning mode: Good-read off-The trigger button must be pressed once to activate scanning. T

Strany 11 - Scanning modes

15 Decoder optimization: If it is enabled, the scanner will optimize the decoder with error correction. This function is not effective for all type

Strany 12 - Programming instruction

i Warning: Ensure that the optional DC adapter works at +5V, especially for the RS-232 interface cable. NOTICE: 1. All software, including

Strany 13 - Interface selection

16 Indication Power on alert: After power-on the scanner will generate an alert signal to indicate a successful self-test. LED indication: After each

Strany 14 - Keyboard wedge

17 Auto-detection scan Auto-detect sensor: By setting Enable, the scanner will start operating if any nearby object has been detected. The lase

Strany 15

18 UPC-A Read: Format Leading zero Data digits (11 digits) Check digitCheck digit verification: The check digit is optional. Check digit trans.: By

Strany 16 - RS-232 interface

19 UPC-E Read: Format Leading zero Data digits (6 digits) Check digitsCheck digit verification: The check digit is optional and made as the sum of th

Strany 17

20 EAN-13 Read: Format Data digits (12 digits) Check digit Check digit verification: The check digit is optional and made as the sum of the numerical

Strany 18

21 EAN-8 Read: Format Data digits (7 digits) Check digitCheck digit verification: The check digit is optional and made as the sum of the numerical va

Strany 19

22 Code 39 Read: Format ⋆ Data digits (variable) Check digit (optional) ⋆Check digit verification: The check digit is optional and made as the sum m

Strany 20 - Indication

23 SETUP Option bar code Option Alpha. entry Read Disable Enable 00 01* Check digit verification Disable Enable 00* 01 Check digit transmissi

Strany 21 - Auto-detection scan

24 Interleaved 2 of 5 Read: Format Data digits (Variable) Check digit (optional) Check digit verification: The check digit is made as the sum module

Strany 22

25 Industrial 2 of 5 Read: Format Data digits (variable) Max./Min. code length: Refer to Max./Min. code length of Code 39. Code ID setting: Refer to C

Strany 23

ii Contents Technical specifications ...

Strany 24

26 Matrix 2 of 5 Read: Format Data digits (variable) Check digit (optional) Check digit verification: The check digit is made as the sum module 10 of

Strany 25

27 Codabar Read: Format Start Data digits (variable) Check digit (optional) End Check digit verification: The check digit is made as the sum module

Strany 26 - Code 39

28 Code 128 Read: Format Data digits (variable) Check digit (optional)Check digit verification: The check digit is made as the sum module 103 of all

Strany 27 - “⋆” as data character

29 Code 93 Read: Format Data digits (variable) 2 check digits (optional)Check digit verification: The check digit is made as the sum module 47 of the

Strany 28 - Interleaved 2 of 5

30 Code 11 Read: Format Data digits (variable) Check digit 1 (optional ) Check digit 2 (optional)Check digit verification: The check digit is present

Strany 29 - Industrial 2 of 5

31 MSI/Plessey Read: Format Data digits (variable) Check digit 1 (optional) Check digit 2 (optional) Check digit verification: The MSI/Plessey h

Strany 30 - Matrix 2 of 5

32 UK/Plessey Read: Format Data digits (variable) 2 check digits (optional)Check digit verification: The UK/Plessey has one or two optional check dig

Strany 31 - Codabar

33 UCC/EAN 128 Read: Format Data digits (variable) Check digit (optional) Check digit verification: The check digit is made as the sum module 103 of

Strany 32 - Code 128

34 China Post Read: Format 11 Data digits Max. /Min. code length: Refer to Max./Min. code length of Code 39. The code length of China Post is 11. C

Strany 33 - Code 93

35 GS1 DataBar (GS1 DataBar Truncated) GS1 DataBar Truncated is structured and encoded the same as the standard GS1 DataBar format, exce

Strany 34 - Code 11

iii String transmission ...

Strany 35 - MSI/Plessey

36 GS1 DataBar Limited Read: Format 16 Data digits Code ID setting: Refer to Code ID setting of UPC-A. Insertion group selection: Refer to Insertion g

Strany 36 - UK/Plessey

37 GS1 DataBar Expanded Read: Format Data characters (variable) Code ID setting: Refer to Code ID setting of UPC-A. Insertion group selection: Refer t

Strany 37 - UCC/EAN 128

38 PDF417 This decoder is only applied with a specified firmware. The symbol size in the standard of PDF417 says, number of rows: 3 to 90, and number

Strany 38 - China Post

39 MicroPDF417 This decoder is only applied with a specified firmware. Read: Format Data characters (variable) Max. /Min. code length: Refer to Max./M

Strany 39

40 China Finance Note: This type of barcode is not Omni-directionally decodable. The encodable character set includes numeric 0 to 9. Among the sym

Strany 40 - GS1 DataBar Limited

41 SETUP Option bar code Option Alpha. entry Read Disable Enable 00 01* Max. code length 00-99 00-99 10* Min. code length 00-99 00-99 10*

Strany 41 - GS1 DataBar Expanded

42 G1-G6 & FN1 substitution string setting Format of barcode data transmission Prefix Code name Preamble Code ID Code length Code data Code ID

Strany 42

43 FN1 substitution string setting: The FN1 character (0x1D) in an UCC/EAN128 barcode, or a Code 128 barcode, or a GS1 DataBar barcode can be substit

Strany 43 - MicroPDF417

44 SETUP Option bar code Option Alpha. entry Prefix string setting 0-22 characters None 00-FF16 00* Suffix string setting 0-22 characters <EN

Strany 44 - China Finance

45 G1-G4 string position & Code ID position Format of barcode data transmission Prefix Code name Preamble Code ID Code length Code data Code I

Strany 45

1 Technical specifications Table 1 Technical specifications Input voltage 5 VDC ± 0.25V Power 500 mW (Operating); 950 mW (Max.) Current 100 mA (Ope

Strany 46

46 String transmission Note: The information in this chapter is closely related to the chapter of String setting. Format of barcode data transmission

Strany 47

47 SETUP Option bar code Option Alpha. entry Prefix transmission Disable Enable 00* 01 Suffix transmission Disable Enable 00 01* Code name transm

Strany 48

48 Test Chart UPC-A UPC-E EAN-8 EAN-13 Code 39 Code 32 A908765439 Code 128 Interleaved 2 of 5 Industrial 2 of 5 Matrix 2 of 5 Code 93 UCC/E

Strany 49

49 Test Chart (Continued) MSI/Plessey UK/Plessey ISBN/ISSN China Post GS1 DataBar (GS1 DataBar Truncated) GS1 DataBar Limited GS1 DataBar Ex

Strany 50 - String transmission

50 Troubleshooting Problem Possible causes Possible solutions No power to the scanner. Check the system power. Ensure the power supply is connected.

Strany 51

51 Maintenance Cleaning the exit window is the only maintenance required. A dirty window may affect scanning accuracy. 1. Do not allo

Strany 52 - Test Chart

52 Assembling the stand 1. See the figure above, tighten the screws. 2. Bend the neck to the desired position for scanning. 3. Screw mounting: S

Strany 53 - Test Chart (Continued)

53 ASCII Table for keyboard wedge for RS-232 H L 0 1 0 1 0 Null NUL DLE 1 Up F1 SOH DC1 2 Down F2 STX DC2 3 Left F3 ETX DC3 4 Right

Strany 54 - Troubleshooting

54 Barcode representing control character Up ↑ Down ↓ Left ← Right → Page Up Page Down Backspace Tab Home End Enter Insert Delete F1 F2

Strany 55 - Maintenance

55 Return default parameters & others WARNING: Default value initialization If you wish to return the scanner to all the factory default setti

Strany 56 - Assembling the stand

2 Default setting for each barcode Table 2 Default setting for each barcode Code type Read enable Check digit verification Check digit transmissionMin

Strany 57 - ASCII Table

56 Configuration alphanumeric entry barcode

Strany 58

3 Decode zone High-Density series Long-Range series

Strany 59

4 Dimensions

Strany 60

5 Parts of the scanner Figure 1 ① Exit window ② LED ③ Trigger ④ Cable interface port ⑤ Release-hole of the cable Figure 2 Remove the interface